{"id":6215,"date":"2019-12-10T15:56:03","date_gmt":"2019-12-10T15:56:03","guid":{"rendered":"http:\/\/dexoncanada.com\/fieldtest\/?p=6215"},"modified":"2020-04-02T20:30:48","modified_gmt":"2020-04-02T20:30:48","slug":"mdvils-series-vent-fan-2","status":"publish","type":"post","link":"https:\/\/dexoncanada.com\/fieldtest\/?p=6215","title":{"rendered":"MDVILS Series Vent Fan"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<div class=\"wp-block-file\"><a href=\"http:\/\/dexoncanada.com\/fieldtest\/wp-content\/uploads\/2019\/11\/MDVILS-SERIES-OWNERS-MANUALS-1.pdf\">MDVILS OWNER&#8217;S MANUAL<\/a><a class=\"wp-block-file__button\" href=\"http:\/\/dexoncanada.com\/fieldtest\/wp-content\/uploads\/2019\/11\/MDVILS-SERIES-OWNERS-MANUALS-1.pdf\" download=\"\">Download<\/a><\/div>\n<div>\u00a0<\/div>\n\n<p>MDVILS vent fans are suitable for indoor inline or wall mounted applications with either a 4\u201d (100mm) or 6\u201d (150mm) air inlet collar; either on the side or the top and either a 4\u201d (100mm) or 6\u201d (150mm) diameter bottom discharge outlet. Please note Dexon does not provide a rigid mounting flange.<\/p>\n\n<p>NOTE:<br \/>Dexon vent fans are intended to provide continuous positive pressure<br \/>ventilation in climates <strong>NOT REQUIRING<br \/>TEMPERING<\/strong> of the supply air.<\/p>\n\n<p>This equipment is suitable for use in Class 1, Division 2, Groups C and D, Temp Code<br \/>T4 or Non-Hazardous Locations, General Enclosure.<\/p>\n\n<p><strong>Vent Fan Specifications<\/strong><\/p>\n<br \/>\n<ul>\n<li>Power Supply &#8211; 120VAC, 60Hz, 240WATT Max input to Vent Fan.<\/li>\n<li>Blower: 24VDC brushless backward curved motorized impeller.<\/li>\n<li>330CFM @ 0\u201dSP.<\/li>\n<li>Low Voltage Interfacing between Vent Fan &amp; Status Indicator\/Controller.<\/li>\n<li>Dimensions 825mmH x 300mmSQ.<\/li>\n<li>Inline or Wall mounted with top or side air inlet collar and can be either four or six inch diameter.<\/li>\n<li>Wall mounting brackets provided.<\/li>\n<li>Four inch (100mm) or six inch (150mm) diameter flat bottom discharge outlet with discharge pipe adapter plate, c\/w gasket.<\/li>\n<\/ul>\n\n<p><strong>Vent Fan Features<\/strong><\/p>\n<br \/>\n<ul>\n<li>Status Indication provided.<\/li>\n<li>Indication of blower rotation when in High\/Full speed only.<\/li>\n<li>Toggle switch on Status Indicator\/Speed Controller for switching from Low\/Idle speed to High\/Full speed.<\/li>\n<li>Onboard adjustable ranges for both Low\/Idle and High\/Full speeds.<\/li>\n<li>Provisions for Optional Low Temperature Shut Down (thermostat by others).<\/li>\n<li>Blower Boost Start.<\/li>\n<\/ul>\n\n<p><strong>Vent Fan Requirements<\/strong><\/p>\n<br \/>\n<ul>\n<li>Status Indicator\/Controller must be installed in appropriate enclosure remote from hazardous locations<\/li>\n<li>Class 1, Division 2 rated units must be fused remote in a Non-Hazardous Location<\/li>\n<li>Ordinary Location Units Fused Internally.<\/li>\n<li>Vent Fans must run continuously<\/li>\n<\/ul>\n\n<p><strong>Please refer to owner\u2019s manual for<br \/>more information<\/strong><\/p>\n<p>\u00a0<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>MDVILS Series vent fans are  suitable for indoor inline or wall mounted applications with 6\u201d (150mm) air inlet collar; either on the side or the top and either a 4\u201d (100mm) or 6\u201d (150mm) diameter bottom discharge outlet. Status and Fan Stopped indication provided.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/posts\/6215"}],"collection":[{"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6215"}],"version-history":[{"count":11,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/posts\/6215\/revisions"}],"predecessor-version":[{"id":6500,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=\/wp\/v2\/posts\/6215\/revisions\/6500"}],"wp:attachment":[{"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6215"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=6215"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dexoncanada.com\/fieldtest\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=6215"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}